MCB Breaker Price in Pakistan: Single, Double and Triple Pole Types, Amp Ratings, Curves and Brand Ranges
MCB breaker price in Pakistan starts at about PKR 300 for a basic single-pole breaker and rises with the pole count, the rating and the brand. An MCB, or miniature circuit breaker, protects a household circuit from overload and short circuit and is the part you switch off at the board. This page explains the pole types, how to read a rating and curve, indicative rates by brand and how to match an MCB to a circuit. Panel work should be done by a licensed electrician. For the full set, see the circuit breaker overview.
What an MCB does
An MCB trips when the current is higher than its rating for too long, which is an overload, or very suddenly, which is a short circuit. It resets by hand. Each MCB protects one circuit, such as lights, sockets or an air conditioner, so a fault on one circuit does not take the whole house off.
Single, double and triple pole
A single-pole MCB switches the live wire of a normal home circuit. A double-pole MCB switches live and neutral together and is used as an isolator for a main or a heavy appliance. Three- and four-pole breakers serve three-phase supplies in shops and workshops. The pole count must match the circuit, which is something a licensed electrician decides.
MCB breaker price in Pakistan
Rates depend on pole count, rating and brand. These indicative ranges show common retail figures.
| Item | Indicative range |
|---|---|
| Single-pole MCB, 6 to 32 A, local to mid brands | PKR 300 - 1,200 |
| Double-pole MCB, mid brands | PKR 900 - 2,500 |
| Three-pole MCB, 63 A, mid brands | PKR 2,500 - 6,000 |
| Three-pole MCB, 125 A, premium | From about PKR 10,900 |
| Premium European MCB, single pole | From about PKR 6,000 |
Prices move with brand, model, size and stock. Use these ranges to judge a quote, then compare the exact model and what is included.

Reading the rating and curve
The marking shows the rated current in amperes, the curve letter and the breaking capacity. Curve B trips at lower surge, curve C suits most homes and curve D suits motors with a strong start current. A 6 kA breaking capacity is common for homes. A higher number is safer where the supply is strong.
Common amp ratings and uses
- 6 to 10 A. Lights and fans.
- 16 to 20 A. Wall sockets and small appliances.
- 25 to 32 A. Air conditioner, geyser, oven or a long run of sockets.
- 40 to 63 A. Sub-main or main supply for a small house.
Ratings should always match the cable size, which our wire and cable guide explains.
Brand ranges
Basic MCB starting prices differ by brand, and the tier usually reflects the build and the breaking capacity. See the circuit breaker brands guide for more.
| Item | Indicative range |
|---|---|
| Himel and Chint, from | About PKR 760 - 900 |
| LS Electric, from | About PKR 950 |
| Schneider Electric, from | About PKR 1,150 |
| Orange Electric, from | About PKR 1,200 |
| ABB, from | About PKR 6,000 |
Prices move with brand, model, size and stock. Use these ranges to judge a quote, then compare the exact model and what is included.

Installing and replacing an MCB
MCBs clip onto a DIN rail in the distribution board. Switch off the main supply before any work, and let a licensed electrician do the wiring. Loose terminals cause heat and burn marks, so the connections must be tight and the wire ends clean.
When an MCB keeps tripping
If an MCB trips again after one reset, there is an overload or a fault. Unplug devices on that circuit, then reset it once. A repeat trip means an electrician should check the wiring and the appliances. Do not replace it with a larger breaker, because that removes the protection for the wire.
Frequently Asked Questions
A single-pole MCB generally costs about PKR 300 to 1,200 from local and mid brands, a double-pole MCB about PKR 900 to 2,500 and a three-pole MCB from about PKR 2,500, with premium European brands and larger ratings costing more.
MCB stands for miniature circuit breaker. It is a small automatic switch that protects a circuit against overload and short circuit and is reset by hand once the cause of the fault is found. Most home distribution boards are full of them, one for each circuit, so an electrician can isolate a single area.
Curve C suits most homes because it handles the normal start surge of lights and appliances. Curve B is more sensitive and suits long cable runs, while curve D suits motors with a strong start current. Check the marking on the breaker face, and ask your electrician if a motor or compressor load needs a different curve.
Socket circuits commonly use 16 to 20 A, depending on the cable size. The breaker must protect the wire, so the rating should come from the cable and the load, which a licensed electrician should confirm. A common home layout uses 16 A on a socket ring with suitable cable, but the actual choice depends on your wiring.
Panel work should be done by a licensed electrician. Switch off the main supply first, and make sure the new breaker matches the old one in rating, poles and curve. Loose terminals cause heat, so wiring must be done carefully.
Send the rating, the poles and the number of ways on WhatsApp. We confirm what we can supply and reply with a written rate that lists the brand, rating and warranty, so you can compare quotes from different sellers on the same scope.
Need MCB breakers?
Send the room size, the item and a photo. We reply with a written rate.